7 devices 7 brands

Gator Protocol (0x2424 binary / 0x80 position)

Gator on TCP 5052: 0x2424 binary with type 0x80 position, 0x82 alarm, or 0x8E blind, and a 0x21 0x0D reply.

Positions go to this server

gps.traxelio.com:5052 TCP
I already have a tracker

Connect your tracker

Enter your tracker IMEI to see whether Traxelio recognizes the model before you start setup.

Point this protocol at Traxelio

Point Gator at Traxelio

  1. 1

    Capture a Gator fingerprint

    Confirm a binary record that opens with 0x2424 and a plot type 0x80, 0x81, 0x82, or 0x8E.

  2. 2

    Point Gator at 5052

    Configure only Gator to TCP 5052. Gator on 5052 is not Flexible Report on 5227 or GPS056 on 5141.

  3. 3

    Expect the 0x21 reply

    Gator is answered 0x2424, type 0x21, then 0x0D. That reply is not a map point.

  4. 4

    Prove one Gator fix

    Send one 0x80 record whose flags bit 7 is set and verify a map point.

Still offline after GPS lock

Gator still not landing

Gator aimed at the wrong port

Gator on 5052 is not Flexible Report on 5227 or GPS056 on 5141.

Alarms only, empty map

Type 0x82 can plot when flags bit 7 is set. Heartbeat 0x21 and status 0x83 will not invent a point.

0x7E sent here

Flexible Report 0x7E will not match Gator. Move those units to 5227.

FAQ

Gator leftover questions

What opens a Gator record?

Two bytes 0x2424, then a type byte, then a 16-bit length.

Which Gator types plot?

0x80 position, 0x81 rollcall, 0x82 alarm, and 0x8E blind area. Heartbeat 0x21 and status 0x83 do not.

Does Gator send an ACK?

Yes. Traxelio replies 0x2424, type 0x21, then 0x0D after a known unit.

How is a Gator unit bound?

A 15-digit IMEI with a Luhn check on the M588 path, or a 4-byte packed unit id tried with and without a leading 1.

Can a Gator unit run SMS setup or a controlled-action flow?

This dialect is positions only. There is no SMS family on this row.

T
Trax
Online
Say hello to Trax!