8 devices 1 brand

RST Protocol (RST; ... FIM;)

RST on UDP 5196: RST; A or L, model, 9-digit serial, type, optional lat/lon with valid 0/1, FIM; ACK type 6.

Positions go to this server

gps.traxelio.com:5196 TCP
I already have a tracker

Connect your tracker

Enter your tracker IMEI to see whether Traxelio recognizes the model before you start setup.

Point this protocol at Traxelio

Point RST at Traxelio

  1. 1

    Capture an RST fingerprint

    Confirm a semicolon line that opens RST; and closes FIM; with a 9-digit serial.

  2. 2

    Point RST at 5196

    Configure only RST to UDP 5196. RST on 5196 is not Robotrack on 5163 or S168 on 5204.

  3. 3

    Do not treat the type-6 reply as a fix

    Traxelio answers RST;A;model;revision;serial;index;6;FIM;. That reply can leave before coordinates parse.

  4. 4

    Prove one RST fix

    Send one RST; line whose valid flag is 1 on 5196 and verify a map point.

Still offline after GPS lock

RST still not landing

RST aimed at the wrong destination

RST on 5196 is not Robotrack on 5163 or S168 on 5204.

Type-6 reply seen, empty map

The RST;A;...;6;FIM; reply is not a plot. Valid flag must be 1 with lat/lon.

Session up, empty map

Valid flag 0 binds the serial and will not plot. Type 134 stores a result on the last fix only.

FAQ

RST leftover questions

Does RST send Concox 0x7878 frames?

No. RST wraps a semicolon line that opens RST; and closes FIM;. Concox families use 0x7878 binary login.

Which valid flag plots an RST fix?

1 plots. 0 binds the serial and will not plot.

Does RST send an ACK?

Yes. Traxelio answers RST;A; plus model, revision, serial, index, type 6, and FIM;. That reply is not a map point.

Where is the RST serial?

The 9-digit field after model and revision, still inside the RST; ... FIM; line.

Can an RST unit run SMS setup or a controlled-action flow?

This dialect is positions only. There is no SMS family on this row.