1 device 1 brand

Svias Protocol ([...] ACK @)

Svias on TCP 5168: [ four-digit versions, IMEI, degree-minute lat/lon ]; reply is a single @ byte.

Positions go to this server

gps.traxelio.com:5168 TCP
I already have a tracker

Connect your tracker

Enter your tracker IMEI to see whether Traxelio recognizes the model before you start setup.

Hardware that speaks this protocol

Devices that speak Svias

Point this protocol at Traxelio

Point Svias at Traxelio

  1. 1

    Capture a Svias fingerprint

    Confirm a line that opens with [ and closes on ]. Reject $1,D001 as STL 060.

  2. 2

    Point Svias at 5168

    Configure only Svias to TCP 5168. Svias on 5168 is not STL 060 on 5060 or Sabertek on 5166.

  3. 3

    Wait for the @ ACK

    A known unit is answered with a single @ byte.

  4. 4

    Prove one Svias fix

    Send one envelope whose output bit 0 is set on 5168 and verify a map point.

Still offline after GPS lock

Svias still not landing

Svias aimed at the wrong host path

Svias on 5168 is not STL 060 on 5060 or Sabertek on 5166.

Session up, empty map

Output bit 0 must be set. Without it the IMEI can bind and the map stays empty.

@ ACK seen, still no point

The @ reply only proves the socket. A valid fix still needs output bit 0 plus lat/lon.

FAQ

Svias leftover questions

Does Svias send $1,D001 lines?

No. Svias opens with [ and closes on ]. STL 060 starts at $1, then IMEI, then D001.

What byte does Svias reply?

A single @. That byte is the whole handshake.

Which bit marks a valid Svias fix?

Output bit 0 must be set. Without it the fix is marked invalid and will not plot.

Where is the Svias IMEI?

After two 4-digit version fields and the index, before the hour-meter.

What is input bit 0 on Svias?

SOS. Input bit 4 is ignition.

T
Trax
Online
Say hello to Trax!