Anytrek on TCP 5177: 0x7878 binary, little-endian length, type, 8-byte IMEI, lat/lon / 1800000, bit 12 valid.
On Traxelio
Point this protocol at Traxelio
Confirm a binary frame that opens 0x7878, carries little-endian length at byte 2, then a type byte and eight IMEI bytes.
Configure only Anytrek to TCP 5177. Anytrek on 5177 is not Tran Sync on 5247 or GT06 on 5023.
Traxelio answers 0x7878 plus the type and zeros, then CR LF. That reply is not proof of a map point.
Send one frame whose flags bit 12 is set on 5177 and verify a map point.
Still offline after GPS lock
Anytrek on 5177 is not Tran Sync on 5247 or GT06 on 5023.
The reply can fire after the type is read. Flags bit 12 must be set and lat/lon must divide by 1800000.
A clear bit 12 binds the IMEI and will not plot. Send a frame whose valid bit is set.
FAQ
No. Anytrek sends packed binary that opens 0x7878, then a little-endian length, a type byte, and an 8-byte IMEI.
Bit 12 of the flags word. A clear bit 12 binds the IMEI and will not plot.
Traxelio answers 0x7878 plus the type, zeros, then CR LF. That reply is not a map point by itself.
Eight bytes after the type. Read them as hex and drop the first two hex characters.
This dialect is positions only. VT1611 is listed.