6 devices 2 brands

Aquila Protocol ($$ event CSV)

Aquila on TCP 5089: $$ event CSV, serial plus event code, A/V, closed by a star checksum.

Positions go to this server

gps.traxelio.com:5089 TCP
I already have a tracker

Connect your tracker

Enter your tracker IMEI to see whether Traxelio recognizes the model before you start setup.

Point this protocol at Traxelio

Point Aquila at Traxelio

  1. 1

    Capture an Aquila fingerprint

    Confirm $$ plus an event code and A/V. This is not FOLLOWIT, on 5109.

  2. 2

    Point Aquila at 5089

    Configure only Aquila to TCP 5089. Aquila on 5089 is not Appello on 5109.

  3. 3

    Bind the Aquila serial

    The serial field after the client token is the device key.

  4. 4

    Prove one Aquila fix

    Send one A-status $$ line on 5089 and verify a map point.

Still offline after GPS lock

Aquila still not landing

Aquila aimed at the wrong port

Aquila on 5089 is not Appello on 5109.

Events never fire

Event extras may be off in the unit. An A-status head still plots.

Aquila session up, empty map

A void V record will not plot. Wait for an A-status $$ line.

FAQ

Aquila leftover questions

Does Aquila send Concox 0x7878 frames?

No. Aquila is ASCII that starts with $$ and ends with a star checksum. Concox families use 0x7878 binary login.

Is Aquila the same as Appello FOLLOWIT?

No. Appello uses FOLLOWIT, on 5109. Aquila uses $$ plus an event code on 5089.

Why does an Aquila line bind without a map fix?

A void V record will not plot. The shared head must carry A plus latitude and longitude.

Do all Aquila lines carry fuel and OBD?

No. Several tails share the same $$ head. Fuel, OBD, DTC, satellites, and sensor blocks are optional.

Can an Aquila unit run SMS setup or a controlled-action flow?

This dialect is positions only. Catalogue devices include the Track Series, S101, and U101. There is no SMS family on this row.