Blue on TCP 5206: 0xaa length-field TLV, location type 0x01, status 0x12, alarm 0x81, ack 0xa4.
On Traxelio
Point this protocol at Traxelio
Confirm 0xaa then inner type 0x01, not AT2000 AES blocks or BWS UDP CRC8.
Configure only Blue to TCP 5206. Blue on 5206 is not AT2000 on 5128 or BWS on 5260.
When the unit sends type 0x84, Traxelio replies type 0xa4 with an XOR checksum.
Send one inner type 0x01 whose valid bit is set and verify a map point.
Still offline after GPS lock
Blue on 5206 is not AT2000 on 5128 or BWS on 5260.
Type 0x12 updates ignition. Type 0x01 must arrive with a stamp before a point plots.
Type 0x84 expects type 0xa4 inside a 0xaa wrapper with an XOR checksum.
FAQ
No. Blue opens with 0xaa then walks inner types 0x01, 0x12, 0x81, and 0x84.
Type 0x01. Type 0x12 updates ignition. Type 0x81 is an alarm. Neither sets the stamp.
Traxelio replies with type 0xa4 and an XOR checksum inside a 0xaa wrapper.
A numeric unsigned-int string, not a 15-digit IMEI wrap.
This dialect is positions only. There is no SMS family on this row.