3 devices 1 brand

Flextrack Protocol (LOGON / UNITSTAT CSV)

Flextrack CSV on Traccar TCP 5090: index,LOGON,node,iccid then index,UNITSTAT,date/time,N/S lat,E/W lon rows.

Connect your tracker

Enter the tracker IMEI first, then verify your email and continue setup.

Quick answers

Stock Traccar port?

TCP 5090.

Login verb?

LOGON with node id and ICCID.

Position verb?

UNITSTAT with hemisphere-prefixed lat/lon.

Flextrack on Traccar TCP 5090 is comma CSV. FlextrackProtocolDecoder accepts LOGON rows (index,LOGON,nodeId,iccid) for session bind and UNITSTAT rows with yyyymmdd/hhmmss, N/S and E/W hemisphere-prefixed coordinates, speed, course, satellites, battery, GSM, and further hex status fields.

LOGON/UNITSTAT — not Freedom IMEI, labels

Do not confuse with Freedom on 5066 (IMEI, + Lat:/Lon:/Spd: labels) or Genx on 5148 (column-mapped CSV). Flextrack’s identity is the LOGON/UNITSTAT verbs.

Catalogue stance

Stock Traccar reference only. Traxelio lists Flextrack as positions_only.

Setup walkthrough

  1. 1

    Confirm LOGON then UNITSTAT

    ASCII must show LOGON before reliable UNITSTAT binding.

  2. 2

    Aim host at TCP 5090

    Save APN server hostname/IP and port 5090; reboot.

  3. 3

    Capture one UNITSTAT

    Expect yyyymmdd, hhmmss, then N/S and E/W coordinate pairs.

  4. 4

    Read battery/GSM fields

    Battery and GSM columns after satellites prove full UNITSTAT match.

Setup

Public setup commands

Use these rows only after confirming the tracker password and SIM settings. Command families can differ between brands even when they use the same protocol.

Setup guidance

Connection supported

gps.traxelio.com:5090 3 example models

Traxelio can receive this model, but public SMS setup depends on SIM or model settings.

Reference

Configuration reference

Parameter Value
Port 5090

Telemetry fields

GPS Location Speed Altitude Heading / Direction Street Address GPS Accuracy Ignition Status Odometer / Mileage Battery Level

All Models

All Flextrack Devices (3)

Start with the strongest matches, then use pagination or brand pages for the full compatibility list.

Compatible Brands

Brands Using Flextrack Protocol

Common troubleshooting

UNITSTAT without LOGON

Some firmwares still need a prior LOGON for node/ICCID bind — send LOGON first.

Sent to Freedom 5066

Lat:/Lon: labels will not match UNITSTAT. Move to 5090.