GL601 on TCP 5257: length-field binary with 15-digit IMEI, record batches, and TLV dataId 81/82 lon/lat.
On Traxelio
Point this protocol at Traxelio
Confirm a length-prefixed binary frame with TLV dataId 81 or 82. Reject a +RESP:GT capture as GL200 or GL100.
Configure only GL601 to TCP 5257. GL601 on 5257 is not GL200 on 5004 or GL100 on 5003.
GL601 has no reply byte. A parsed dataId 81 or 82 record is enough.
Send one record whose dataId 81 or 82 carries filled lon/lat and verify a map point.
Still offline after GPS lock
GL601 on 5257 is not GL200 on 5004 or GL100 on 5003.
dataId 81 or 82 must carry lon/lat. A record with no coordinate TLV reuses the last fix and will not plot a new point.
This dialect has no reply byte. Check the map, not the socket for an ACK.
FAQ
No. GL601 sends length-prefixed binary records with TLV dataId 81 or 82. The +RESP:GT text row is GL200.
dataId 81 or 82. 81 carries lon, lat, fix time, and speed. 82 also carries HDOP, course, altitude, and sats.
No. There is no reply byte. A parsed dataId 81 or 82 record is enough to plot.
Eight bytes of hex with the first nibble dropped, leaving 15 digits.
This dialect is positions only. GL601 and GL601CEU are listed. There is no SMS family on this row.