Meiligao
Guided setup available
Set reporting interval
W{password},002,1
APN commands depend on the carrier SIM in your tracker, so they are not shown here.
Binary TCP protocol designed by Shenzhen Meiligao Electronics · the third pillar of Chinese OEM GPS protocols alongside GT06 and TK103. Often called "MVT" after the MVT-series fleet trackers that made it widespread.
Positions go to this server
IMEI format: 7-byte BCD (device-printed ID padded with leading zeros, packed two digits per byte)
On Traxelio
Hardware that speaks this protocol
Who ships hardware on this wire
Point this protocol at Traxelio
Confirm the SIM works for data in a phone first. MVT-series devices have a single multi-purpose LED · a dead SIM and a config issue look identical from the LED alone.
Open Meiligao Manager on Windows, plug in the USB-to-serial cable, click Read Parameters. This is faster and more reliable than SMS for the first config · you see the full parameter table at once.
In Manager, set Main Server IP/host to your-server.com and port to 5009. Or via SMS: adminip,000000,your-server.com,5009#. The default admin password is 000000 · change it after first config.
adminip,000000,your-server.com,5009#
apn,000000,internet#
gprs,000000#
password,000000,<new_password># · default 000000 is a security liability on a SIM that could receive any SMS. Pick a 6-digit value and store it with the device record.
Send status,<password># and watch your server log for the heartbeat (command 0x0A) followed by the first position (command 0x9955) after a clean boot with GPS lock. No traffic after the reboot · re-check APN (silent failure mode #1).
Replace {password} with the tracker PIN or password.
Guided setup available
Set reporting interval
W{password},002,1
APN commands depend on the carrier SIM in your tracker, so they are not shown here.
Guided setup available
Set reporting interval
W{password},014,00006
APN commands depend on the carrier SIM in your tracker, so they are not shown here.
Guided setup available
Check settings
{password}WWW
APN commands depend on the carrier SIM in your tracker, so they are not shown here.
Guided setup available
Switch to TCP
W{password},013,1
Set reporting interval
W{password},014,6
APN commands depend on the carrier SIM in your tracker, so they are not shown here.
Still offline after GPS lock
Almost always a header confusion · $$ is not unique to Meiligao (a few other protocols use the same bytes). Check the BCD device-ID field at offset 4 · if it's not 7 BCD bytes matching the printed device ID, the listener is auto-routing to the wrong decoder. Bind Meiligao to its own dedicated port instead of multiplexing.