MiniFinder IP1
Guided setup available
Set upload interval (60s)
TI60S
APN commands depend on the carrier SIM in your tracker, so they are not shown here.
MiniFinder on TCP 5062: bang-typed ASCII ending in semicolon; !1 binds IMEI, !A/!C/!D/!B plot, !3/!4/!5 do not.
On Traxelio
Hardware that speaks this protocol
Point this protocol at Traxelio
Confirm a !1,imei bind and a later !A or !D row with dd/mm/yy slash dates, ending with a semicolon.
Configure only MiniFinder to TCP 5062. MiniFinder on 5062 is not MiniFinder 2 on 5187 or Xexun on 5006.
MiniFinder has no reply byte. A parsed !A or !D lat/lon pair is enough.
Send one !A, !C, !D, or !B line with valid flag bits on 5062 and verify a map point.
Still offline after GPS lock
MiniFinder on 5062 is not MiniFinder 2 on 5187 or Xexun on 5006.
!1 binds the IMEI and will not plot. Send !A, !C, !D, or !B with valid flag bits.
This dialect has no reply byte. Check the map, not the socket for an ACK.
FAQ
No. MiniFinder uses bang-typed ASCII rows that end with a semicolon. Concox families use 0x7878 binary login.
It binds the IMEI for the session and does not plot a point.
!A, !C, !D, and !B carry lat/lon. !3, !4, and !5 reuse the last point.
Bit 6 is SOS. Bit 8 is fall. Bits 9-11 are geofence. Bit 12 is low battery.
This dialect is positions only. There is no SMS family on this row.