PUI Protocol (MQTT JSON rpt hf/loc)

PUI on MQTT 5249: JSON rpt hf or loc, ISO ts, location lat/lon, bear, spd in cm/s, ign on.

Check setup options

Enter the tracker IMEI first so Traxelio can confirm setup options before activation.

Who ships hardware on this wire

Brands using Pui

Point this protocol at Traxelio

Point Pui at Traxelio

  1. 1

    Capture a PUI fingerprint

    Confirm MQTT CONNECT, then a JSON PUBLISH whose rpt is hf or loc with location lat/lon.

  2. 2

    Point PUI at 5249

    Configure only PUI to MQTT 5249. PUI on 5249 is not PST on 5207 or Race Dynamics on 5195.

  3. 3

    Treat PUBACK as bookkeeping

    CONNACK accepted plus PUBACK is not a map point. A plot needs rpt hf or loc.

  4. 4

    Prove one PUI fix

    Publish one JSON body with rpt hf or loc and location lat/lon on 5249 and verify a map point.

Still offline after GPS lock

Pui still not landing

PUI aimed at the wrong port

PUI on 5249 is not PST on 5207 or Race Dynamics on 5195.

PUBACK arrived, empty map

PUBACK is MQTT bookkeeping. rpt must be hf or loc and location must carry lat/lon.

JSON posted, empty map

A rpt other than hf or loc is dropped. CONNECT must already be accepted.

FAQ

Pui leftover questions

Does PUI send Concox 0x7878 frames?

No. PUI is MQTT JSON with rpt hf or loc, a nested location object, bear, spd, and ign. Concox families use 0x7878 binary login.

Which PUI rpt values plot a fix?

hf and loc. Any other rpt is dropped even if location is present.

Does a PUI PUBACK mean a map point landed?

No. PUBACK is MQTT bookkeeping. A plot needs rpt hf or loc plus location lat/lon.

What PUI string marks ignition?

ign equal to on. Any other ign string is treated as ignition off.

Can a PUI unit run SMS setup or a controlled-action flow?

This dialect is positions only. There is no SMS family on this row.