Starcom on UDP 5190: pipe-wrapped comma key=value CSV with unit=, gps_valid=, decimal lat/lon, datetime_actual.
On Traxelio
Hardware that speaks this protocol
Point this protocol at Traxelio
Confirm a UDP datagram wrapped in pipes with unit= and comma key=value pairs. Reject $SLU and && lines.
Configure only Starcom to UDP 5190. Starcom on 5190 is not StarLink on 5136 or Startek on 5222.
Starcom has no reply byte. A parsed gps_valid nonzero line is enough.
Send one |unit=...| line with gps_valid nonzero and decimal lat/lon on 5190 and verify a map point.
Still offline after GPS lock
Starcom on 5190 is not StarLink on 5136 or Startek on 5222.
Without unit= the datagram will not bind. Put the unit key inside the pipes before debugging GPS.
gps_valid must be nonzero. A 0 value binds the unit and will not plot.
FAQ
No. Starcom is ASCII inside pipes: comma key=value pairs such as unit= and gps_valid=. Concox families use 0x7878 binary login.
unit=. A datagram without that key will not bind even when latitude and longitude are present.
The row can still bind. A zero value will not plot. Send a nonzero gps_valid with decimal latitude and longitude.
yyyy/MM/dd HH:mm:ss. velocity is km/h as sent. odometer is kilometres times 1000 in store.
This dialect is positions only. Catalogue devices include Helios, Helios Advanced, Helios Hybrid, and Helios TT. There is no SMS family on this row.